Air Source Heat Pump Replacement in Luton: Upgrading to a Grant Aerona R290

Air Source Heat Pump Replacement in Luton Upgrading to a Grant Aerona R290
Published On: 10th November, 2026

Fixing a Broken Heating System – Grant Aerona R290 Heat Pump Replacement in Luton

When your heating fails, you need a lasting solution. We recently responded to a total breakdown of an LG Therma V R32 air source heat pump at a property in Luton, Bedfordshire. Our technical inspection uncovered a dead PCB alongside a cluster of failing components.

Faced with steep repair costs, the homeowner chose a complete heat pump replacement in Luton. We supplied and installed the highly efficient Grant Aerona R290. This is a premium heat pump which requires a detailed setup. We inspected the existing installation, replacing degraded pipe insulation and cutting out an unnecessary buffer tank. As a result the new system works exactly as the manufacturer intended, without old components holding it back.


Replacing the Old LG Therma V Heat Pump

The customer’s original LG Therma V R32 had suffered a complete breakdown, leaving them needing a solution to get their heating working again.

We identified that the unit required a new PCB and several smaller replacement parts. Rather than spending money repairing the old system, the homeowner decided to invest in a new Grant Aerona R290.

The Grant Aerona is a modern air source heat pump designed to provide efficient heating throughout the year. It uses R290 refrigerant, which has a much lower global warming potential than the R32 used in the previous LG unit.

For the customer, it was an opportunity to move to newer technology while also addressing some issues with the original installation.

As with any air source heat pump installation, it’s important to look at the whole heating system rather than simply swapping one outdoor unit for another.

That’s exactly what we did on this project.

 


Sorting Out the External Pipework

One of the first things we noticed was the condition of the external pipe insulation.

The original lagging wasn’t suitable for prolonged outdoor exposure and had started to fall apart after being exposed to UV rays from the sun.

This might not sound like a major issue, but good pipe insulation is really important when it comes to heat pump efficiency.

The pipes running between the outdoor heat pump and the house carry heated water. If they’re not insulated properly, some of that heat can escape before it reaches the heating system.

Essentially, you’re paying to heat water and then losing some of that heat outside.

We also noticed another problem with the original installation. The clips securing the pipes to the wall had been fitted directly around the pipework, creating what’s known as thermal bridging.

This happens when heat can escape through a point where the insulation is interrupted. In this case, the pipe clips were providing a path for heat to transfer away from the pipes.

It’s one of those small details that can easily be overlooked, but getting it right helps the system perform as intended.

Installing the Correct Pipe Clips

Rather than working around the existing clips, we decided to sort the pipework out properly.

We carefully pulled the external pipes away from the wall, giving us enough room to fit the correct clips and insulation. The new clips sit around the outside of the lagging rather than directly against the heating pipes.

This means the insulation can continue around the pipework without being interrupted by the fixing points, reducing thermal bridging and helping to keep the heat where it belongs.

It’s a relatively simple improvement, but one that makes a difference to the overall quality of the installation.

 


Upgraded external insulation and clips around the lagging

Upgrading to Primary Pro Pipe Insulation

With the pipework repositioned and the new clips fitted, we could replace the old, deteriorating lagging.

For this installation, we used Primary Pro pipe insulation, which is designed for external applications such as air source heat pump installations.

Unlike the original insulation, which had started breaking down in the sunlight, Primary Pro is designed to withstand outdoor conditions when installed correctly.

It helps protect the pipework from the weather while reducing heat loss between the heat pump and the house.

We also made sure every joint was properly sealed using PSB Primary Seal and Bond.

This is an important part of the job because even small gaps between sections of insulation can allow heat to escape and expose the pipework insulation to moisture and weathering.

By sealing each joint, we created a continuous protective layer around the external pipes. The finished pipework looks much tidier, but more importantly, it’s properly insulated and better protected against the elements.

For us, it’s these finishing touches that help make a good heat pump installation.

 


Removing the Existing Buffer Tank

Once we’d sorted the external pipework, we turned our attention to the heating system inside the property.

The original installation included a buffer tank. Buffer tanks can be useful in certain heat pump systems, particularly where additional water volume or hydraulic separation is needed.

However, they’re not always necessary, and in some installations they can introduce additional heat losses or make the system less efficient than it could be.

After assessing this customer’s setup, we determined that the system could operate without the existing buffer tank. We removed it and configured the new Grant Aerona to heat the home’s heating circuit directly.

This is known as a direct or open-loop system.

Why Did We Remove the Buffer Tank?

With the old setup, the heat pump was heating water through a system that included an additional buffer vessel.

By removing the buffer tank and connecting the heat pump directly to the heating circuit, we simplified the installation and removed an unnecessary stage in the heating process.

This means the heat pump can deliver heat directly to the home’s heating system without the additional losses that can occur with some buffer tank arrangements.

It can also help the heat pump operate at lower water temperatures, which is important because heat pumps generally work more efficiently when they don’t have to produce unnecessarily high temperatures.

Of course, every property is different, and buffer tanks do have their place. The system still needs to meet the heat pump manufacturer’s flow and water volume requirements. For this particular installation, though, removing the buffer tank was the better option. It gave us a simpler heating arrangement designed to make the most of the new Grant Aerona.

 


Setting Up Weather Compensation

Another important part of this installation was getting the heating controls set up correctly.

We configured the new Grant Aerona R290 to run using weather compensation.

This is something we always consider carefully when setting up a heat pump because it can make a real difference to how efficiently the system operates.

So, what exactly is weather compensation?

Put simply, it allows the heat pump to adjust the temperature of the water going into your heating system depending on how cold it is outside.

Heat pump controller showing outdoor and indoor temperatures

When the weather is mild, your home doesn’t need as much heat to stay comfortable, so the heat pump can run at a lower water temperature.

As the temperature outside drops, the heat pump gradually increases the heating water temperature to compensate.

Why Is Weather Compensation Better?

One of the biggest advantages of a heat pump is its ability to provide heating efficiently at lower water temperatures.

If you set a heat pump to produce unnecessarily hot water all the time, it will generally use more electricity than it needs to. Weather compensation helps avoid this.

For example, on a mild autumn day, the system might only need relatively low-temperature water to keep the house comfortable.

On a freezing winter morning, it will need to work harder, so the controls automatically increase the target water temperature. Rather than constantly running at a fixed high temperature, the system responds to the conditions outside. This helps keep the home comfortable while giving the heat pump the best opportunity to operate efficiently.

For our customer in Luton, we set up the weather compensation controls to suit their heating system, helping the new Grant Aerona deliver the right amount of heat as the outdoor temperature changes.

It’s another example of why properly setting up a heat pump is just as important as installing it.

 


Why a Heat Pump Replacement Is About More Than the Outdoor Unit

It’s easy to think that replacing an old heat pump is simply a case of disconnecting the existing unit and fitting a new one.

But as this project shows, there’s often more to consider.

The condition of the external pipework, the type of insulation, the way the heating system is connected and how the controls are configured can all affect performance.

In this case, we were able to make several improvements alongside the new installation:

  • New Grant Aerona R290 heat pump: Replacing the failed LG Therma V R32 with a modern, efficient heating system.
  • Improved external pipework: Repositioning the pipes and fitting the correct clips to reduce thermal bridging.
  • Primary Pro insulation: Replacing the old UV-damaged lagging with insulation designed for outdoor use.
  • Properly sealed joints: Using PSB Primary Seal and Bond to protect the insulation from weathering and reduce heat loss.
  • Buffer tank removal: Simplifying the heating system so the heat pump could heat the property directly.
  • Weather compensation: Setting up the controls to adjust the heating temperature according to the weather outside.

Each of these improvements was made with the same goal in mind: to help the customer’s new heat pump operate as efficiently and reliably as possible.

A new heat pump is a significant investment, so we believe it’s important to make sure the rest of the installation is up to the same standard.


Completed Grant Aerona R290 heat pump installation in Luton

The Finished Heat Pump Installation in Luton

With the new Grant Aerona R290 installed, the external pipework properly insulated and the internal heating system simplified, the customer now has a modern heating setup designed around their property’s requirements.

The old LG Therma V has been replaced, the deteriorating insulation has been removed, and the new pipe clips eliminate the direct contact points that were causing thermal bridging.

Inside, the buffer tank has been taken out, allowing the heat pump to heat the system directly, while weather compensation helps manage the heating water temperature throughout the year.

The result is a much tidier installation, with improvements that go beyond simply replacing the broken equipment.

Although actual running costs will depend on the weather, how the home is used and the heating demand, the system has been designed and configured to minimise unnecessary heat losses and support efficient operation.

We’re really pleased with how this installation turned out, particularly the improvements to the external pipework and the simplified heating arrangement.

Every property is different, which is why we design our installations around the home’s heating requirements. You can see another example in our Harpenden heat pump installation case study, where we installed an air source heat pump alongside underfloor heating and radiators.

 


Frequently Asked Questions

Yes, it’s possible to replace an LG Therma V with a Grant Aerona R290, provided the new unit is suitable for the property and heating system. We assess the existing installation before recommending the best replacement option.

The Grant Aerona R290 uses modern heat pump technology and a low global warming potential refrigerant. Whether it is more efficient than an existing heat pump depends on the models being compared, the heating system and how both units are installed and operated.

Not always. Some systems require a buffer tank for additional water volume or hydraulic separation, while others can operate efficiently without one. We assess each installation to determine the most suitable arrangement.

External heating pipes carry warm water between the heat pump and your home. Good insulation reduces heat loss and helps protect the pipework from the weather. Poor or damaged insulation can lead to unnecessary energy waste.

Weather compensation automatically adjusts the heating water temperature based on the outdoor temperature. This allows the heat pump to provide more heat when it’s cold and less when the weather is mild, helping improve efficiency.

Yes. Cosy Home carries out heat pump installation and replacement work in Luton and surrounding areas across Bedfordshire, Buckinghamshire and Hertfordshire. Contact our team to discuss your existing system and requirements.

 


 

Thinking About Replacing Your Air Source Heat Pump?

If you’ve already got an air source heat pump that’s broken down, becoming unreliable or not performing as well as it should, it doesn’t always mean you need a complete replacement.

Sometimes a repair is the most sensible option. Regular air source heat pump servicing can also help identify potential problems before they develop into more expensive breakdowns. However, if your system is getting older or you’re considering an upgrade, it’s worth looking at the entire installation to see whether there are opportunities to improve efficiency.

At Cosy Home, we install, replace and work on air source heat pump systems for homeowners in Luton, Bedfordshire, Buckinghamshire and Hertfordshire.

Whether you’re looking to replace an existing LG Therma V, upgrade to a Grant Aerona R290 or simply get some advice about your current heating system, we’re happy to help.

 


 

Get in touch with Cosy Home today to discuss your heat pump installation or replacement.

Share This Blog!